Vital signs monitor ECG, SpO2, NIBP, RESP and TEMP

It finishes in
day(s)
Be quick
It finishes in
day(s)
-19%
Special Price €828.95 Excluding VAT €673.94 Regular Price €1,027.95
It finishes in
day(s)
Be quick
It finishes in
day(s)
-19%
In stock
Pay securely with:
Ref: 159-VS2000
Vital signs monitor for use in laboratories, hospitals and clinics for monitoring adults and newborn patients. In its 7” inch LCD screen it offers measurements of heart rate, ECG, oxymetry, NIBP, RR, and TEMP.
Description

This vital signs monitor is intended to be used in laboratories and hospital or clinic areas, where monitoring systems are needed. It provides a fast and reliable measurement for both adult and newborn patients.

Features:

Heart rate / pulse: is measured with the ECG, oximetry, and noninvasive blood pressure (NIBP) parameters.

Electrocardiogram (ECG):

  • The monitor provides continuous 5-lead ECG processing, with standard derivation selections and electrocautery discharge filtering.
  • You can display up to 3 waveform channels simultaneously.

Oximetry: The oximetry parameter provides continuous noninvasive monitoring of oxygen saturation (% SpO2) in the arterial and pulse (PR) rates.

Non-invasive blood pressure (NIBP):

  • The noninvasive blood pressure (NIBP) parameter provides the values ​​of systolic, diastolic, and mean arterial pressure, in addition to the heart rate.
  • NIBP measurements can be made in automatic, manual or STAT modes.

Respiratory frequency (RR): The monitor provides the respiratory frequency and the Resp waveform by measuring the impedance between 2 ECG electrodes at the patient's thorax.

Temperature (TEMP): There are two independent temperature control channels (T1 and T2).

Display:

  • The monitor has a high resolution color LCD screen and high contrast.
  • Provides a continuous, real-time image of up to 4 waveforms.
  • It also shows the measured values, chronological data, measurement trends, alarm limits and patient information.

Internal battery:

  • The rechargeable internal Li battery is Mainly intended for backup and usage switching.
  • The expected lifespan of the battery is 2 to 5 years, depending on usage.
  • A fully charged battery will last 2 to 3.5 hours, depending on the use of the monitor.

Technical specifications:

Display:

  • 7 inch high resolution, active matrix flat screen (TFT or Thin film transistor).
  • Resolution: 800 × 480 pixels.

Indicators:

  • Work status LED
  • AC power LED
  • Battery charge LED
  • Battery power LED
  • Alarm silence LED

Alarm volume: from 45dBA to 85 dBA, 1 meter away (adjustable).

ECG:

  • Heart rate range: 20-350 bpm
  • Heart Rate Accuracy: 2 bpm or ± 2 % (whichever is greater)
  • QRS detection range: 0.5 to 5 mV
  • Pacemaker pulse detection: Amplitude: 2 mV to 700 mV
  • Detection of duration: 0.1 - 2.0
  • Heart rate range alarm:
    • High: 20-350 bpm and deactivated
    • Low: 20-350 bpm and deactivated
  • Average of heart rate: Average of 8 seconds set
  • Selection of leads: I, II, III, V, aVR, aVL, or aVF (5 leads)
  • Gain display settings: X1/4, X1/2, X1, X2, X4
  • Input range: -5,0 mV to +5,0 mV
  • Frequency response: 0.05 Hz to 40 Hz
  • Input impedance: Differential > 5 Mohms, as required and tested by ANSI / AAMI EC-13.
  • Leaks: < 10 uA
  • Patient isolation: > 4000 VCA
  • Visualisation of waveforms: 120 Hz; 6.25, 12.5, 25, or 50 mm/s
  • Update of frequency digits: 1 Hz

SpO2:

  • Range of SpO2: 0-100 % of functional saturation
  • SpO2 precision:
    • ± 2% @ 70-100 %
    • <70% unspecified
  • Frequency range of the pulse: 20-350 bpm
  • Frequency precision of the pulse: ± 2 bpm or ± 2 % (whichever is greater)
  • Alarm ranges of SpO2:
    • High: 50 - -100 % and deactivated
    • Low: 50 - -100 % and deactivated
  • Calbration: SpO2 default calibration on 50 % to 100 % range, using human blood samples for the functional saturation.

NIBP:

Measurement of blood pressure:

  • Method of measurement: Oscillometric with reducing deflation
  • Range: Systolic: 40 to 270 mmHg
  • Average arterial: 30 to 220 mmHg
  • Diastolic: 20 to 200 mmHg
  • Pulse: 25 to 300 bpm
  • NIBP precision: Algorithm based on the human algorithm that meets or exceeds the precision requirements of the norms ANSI/AAMI SP10:1992 and 2002 for non-invasive arterial pressure through the oscillometric method.

Configuration of inflation pressure:

  • Time of measuring: 30 to 50 seconds (typical), 120 seconds (maximum)
  • Predefined inflation pressure:
    • 120 mmHg - Adult
    • 100 mmHg - Paediatric
    • 90 mmHg - Neonatal
  • Calibration: Calibration at the factory
  • AUTO interval times: 2, 3, 5, 10, or 30 minutes, or 1, 2 hours 20-260 (in 1 mmHg steps), and deactivated
  • Alarm range: 25- 250 lpm, ± 2% or ± 3 lbpm (whichever is greater)
  • Pulse frequency precision: 251-300 bpm, ± 5 %

Respiratory frequency (RESP):

  • Range: 0-120 breaths per minute (bpm)
  • Precision: ±1 bpm
  • Resolution: 1 bpm
  • RESP alarm range:
    • High: 0-120 bpm (1 bpm steps) and deactivated
    • Low: 0-120 bpm (1 bpm steps) and deactivated

Temperature (TEMP):

  • Channel: Two
  • Range: 25-45ºC
  • Precision:± 0.2ºC plus the tolerance of the temperature sensor
  • Resolution: 0.1ºC
  • Alarm range of TEMP:
    • High: 35.5-43.5ºC and deactivated in increments of 0.1
    • Low: 35.5-43.5ºC and deactivated in increments of 0.1

Voltage requirements: AC entry: 100 to 240 V, 50/60 Hz

Dimensions:

  • Width: 300 mm.
  • Length: 180 mm.
  • Height: 130 mm.
  • Equipment weight: 2 Kg approx.
  • Total weight: 3.6 Kg approx.

Environmental protection:

  • Temperature:
    • From 0 to 50 0C (operation)
    • From -40 to 75 0C (storaging)
  • Humidity:
    • From 15 to 95 % (operation)
    • From 10 to 95 % (storaging)

Classification of the equipment:

  • Type of protection (from electrocutions): TYPE I (internal power)
  • Operational mode: Continuous
  • Protection degree (from liquids absorption): IPX1, drop-proof
  • Mobility degree: Portable
  • Protection degree (from electrocutions): CF type
  • Safety requirements: EN60601-1:2002

Includes:

  • Vital signs monitor
  • ECG cable 5 leads
  • Temperature probe
  • Reusable finger oximetry sensor for adults
  • Tube for NIBP with sleeve for adults 27-35 cm
  • Internal battery
  • Power cord
  • Intructions manual

Certification:

  • CE 93/42 directive of Health Products

 