Modern class B autoclave of 18 litres capacity to sterilise used materials in hospitals, laboratories, beauty centres, tattoo studios, etc. Touch LCD display. It features both printer and USB connection.

Description

New class B autoclave with 18 litres of capacity, designed with cutting-edge technology to sterilise tools and materials used in hospitals, laboratories, clinics, tattoo studios, etc. It has user-friendly touchscreen to control all the operations, printer and USB connection to export data.

Programmes:

Programme Temperature Pressure Sterilisation time Total time Type Maximum load Maximum load per tray
Quick S 134 ºC 210 kPa 4 min 11-15 min Solid material without wrapping 1 Kg 0.8 Kg
B Standard 134 ºC 210 kPa 4 min 30-49 min Solid material without wrapping 4.5 Kg 1.5 Kg
Solid or hollow material with double wrap 4 Kg 1.2 Kg
B soft 121º C 110 kPa 20 min 38-54 min Solid material without wrapping 4.5 Kg 1.5 Kg
Solid or hollow with simple wrap 4 Kg 1.2 Kg
Prion 134  ºC 210 kPa 18 min 37-52 min Porous material without wrapping 1.25 Kg 0.4 Kg
Porous material with simple wrapping 1.1 Kg 0.3 Kg
Porous material with double wrapping 0.75 Kg 0.25 Kg
Hollow material with simple wrapping 4 Kg 1.25 Kg
Hollow material with double wrapping 2 Kg 0.6 Kg
B&D Test 134  ºC 210 kPa 3.5 min 28-35 min - - -
Helix Test 134  ºC 210 kPa 3.5 min 28-35 min - - -
Vacuum Test - - - 20-25 min - - -
  • The minimum time required for the autoclave to be ready for being used after connecting it to the power supply is 5 minutes.
  • The maximum temperature of the 134 ºC sterilisation cycle is 137 ºC
  • The maximum temperature of the 121 ºC sterilisation cycle is 124 ºC

Characteristics:

  • Cutting-edge technology and modern design
  • Touch LCD screen with user-friendly interface to totally control the equipment
  • Automatic work with several default sterilisation cycles
  • Surgical stainless steel chamber
  • Built-in printer and USB connection to export the data to a pendrive (included)
  • Tests: Bowie & Dick test, Helix test, vacuum test
  • Materials: wrapped, non-wrapped, solid or hollow, porous
  • Capacity of the water tank: 2.5 l

Safety mechanism:

  • Circuit breaker
    • It protects the equipment from any possibility of failure in the electricty system.
    • Action: Interrupting the energy supply.
  • Fuses
    • Protection against possible short-circuits and overheating in the primary network of the transformer.
    • Action: Temporary interruption (until the temperature has decreased) in the set of bobbins.
  • Safety valve
    • Protection against a possible increase in pressure inside the chamber.
    • Action: Steam exhaust until recovering a normal level of pressure.
  • Micro-switch to control the state of the door
    • It exercises control in the doord adjustment to be able to start a sterilisation cycle.
    • Action: It transmits the signal to alert on the incorrect position of the door.
  • Thermostat for the heating resistors in the chamber
    • Protection before a possible overheating in the resistors in the steam generator.
    • Action: It interrupts the power supply towards the heating resistors in the chamber.
  • Thermostat for the resistors in the steam generator
    • Protection before a possible overheating in the heating resistors in the steam generator.
    • Action: It interrupts the power supply towards the resistors in the steam generator.
  • Self-levelling of the hydraulic system
    • The hydraulic system will bring back its natural pressure if the sterilisation cycle has been interrupted manually.
    • Action: Automatic restoring of atmospheric pressure inside the chamber
  • Door locking system
    • Effective protection to prevent the door to open accidentally.
    • Action: Effective protection to prevent the door to open accidentally.

Technical data:

  • General size: 45 × 48.5 × 62 cm
  • Chamber’s size: Ø 25 × 32.5 cm
  • Net weight: 50 Kg
  • Power rating: 1750 VA
  • Frequency: 50 Hz
  • Circuit breaker: 400 V
  • Operation temperature: 5 ºC ~ 40 ºC
  • Operation Humidity: Max. 80 % (non condensed)
  • Maximum level of noise: <70 dB
  • Atmospheric pressure: 76 kPa ~106 kPa

Included accessories:

  • (×5) Trays
  • (×1) Trays support
  • (×2) Drain pipes
  • (×1) Door gasket
  • (x1) Handle for trays

Optional accessories and spare parts:

  • 922-ROLLPAPER - Paper roll for printer