Autoclave Black Dragon 12 Litres Class B for Tattoo

-10%
Special Price €2,029.99 Excluding VAT €1,650.40 Regular Price €2,254.95
-10%
Available: 08/07/2024
Pay securely with:
Ref: 922-STE-B12DNE
Autoclave Black Dragon 12 liters and class B with finishes in black color for Tattoo studios.
Description

Autoclave Black Dragon 12 liters class B for tattoo studios.

Programmes:

 

Programmes Temperature Pressure Sterilisation time Total time Type Max. load Max. load per tray
Solid 134 0C 210 kPa 4 min 14-30 min Solid unwrapped 4 Kg 1.2 Kg
1210C 110 kPa 20 min 30-45 min
Wrapped 134 0C 210 kPa 4 min 30-45 min Solid unwrapped 3.5 Kg 1.1 Kg
121 0C 110 kPa 20 min 35-55 min Solid or hollow simple wrapped 3.5 Kg 1.1 Kg
Liquid 134 0C 210 kPa 10 min 30-55 min Liquid 0.80 kg 0.25 kg
121 0C 110 kPa 30 min 35-60 min
Textile 134 0C 210 kPa 8 min

 

30-50 min

Porous unwrapped 1 Kg 0.3 Kg
Porous simple wrapped 0.75 Kg 0.2 Kg
121 0C 110 kPa 30 min 40-60 min Porous double wrapped 0.5 Kg 0.15 Kg
Hollow simple wrapped 3.5 Kg 1 Kg
Solid or hollow double wrapped 1.5 Kg 0.5 Kg
Prion 134 0C 210 kPa 18 min 30-50 min Porous unwrapped 0.1 Kg 0.3 Kg
Porous simple wrapped 0.75 Kg 0.2 Kg
Porous double wrapped 0.5 Kg 0.15 Kg
Hollow simple wrapped 3.5 Kg 1 Kg
Solid or hollow double wrapped 1.5 Kg 0.5 Kg
B&D test 134 0C 210 kPa 3.5 min 22-35 min - - -
Helix test 134 0C 210 kPa 3.5 min 22-35 min - - -
Vacuum test - - - 18-20 min - - -

Safety:

  • A cycle will not start unless the door is firmly closed.
  • An automated system with double hydraulic locking device prevents the door from opening while chamber is pressurized.
  • The safety valves prevent overpressure in the generator and in the chamber.
  • A safety thermostat prevents overheating in the chamber and in the generator.
  • An automatic safety lock prevents accidental opening of the door during the sterilisation. A power protector automatically cuts off power in case of short circuit or if power supply is not very stable.
  • The failure alarm indicates a cycle failure and provides an error code.
  • The door alarm indicates that the door is not properly closed.
  • The low water alarm indicates when the water tank is empty or too full.

 Technical features:

  • Power supply: 220-240V; 50/60Hz; 10A
  • Chamber: 200 x 360 mm
  • Breaker: F16A / 400V
  • Nominal power: 2200VA
  • Sterilisation temperature: 121 0C / 1340C
  • Capacity of the distilled water tank: 2.5 L
  • Working temperature: 5 0C / 40 0C
  • Working relative humidity: Max. 80%, non condensing
  • Overall dimensions: 414 x 365 x 570 mm
  • Net weight: 51 Kg
  • Max. noise level: <70 dB
  • Atmospheric pressure: 76 / 106 kPa

Components:

  • Distilled water tank
  • LCD display
  • Control panel
  • Main power switch
  • Drain connector (distilled and used water tank)
  • USB port
  • Safety valve
  • Ventilation grid
  • Circuit breaker
  • Power cable
  • Rating plate

Accessories included:

  • Steriliser
  • USB
  • 3 instrument trays
  • Tray rack
  • Tray holder
  • Door adjustment tool
  • 2 draining hoses
  • Door gasket
  • User manual

Standards:

  • 93/42/EEC Directive on Medical Devices.
  • 97/23/EEC Directive on Pressure Equipment.
  • EN 13060 Small Steam Sterilisers.
  • EN 61326, EN 61000 Electromagnetic Compatibility.
  • EN 61010-1, UL 61010-1 Safety requirements.
  • EN 61010-2-040, IEC 61010-2-040 Specific requirements for steam sterilisers used for treatment of medical materials.

In the UK this product needs to be inspected and certified anually. Quirumed don´t offer this service and you will need to find your own local techncian who can do this. We do however have a technical service based in Spain to cover the product during the warranty period

AUTOCLAVE - step by step:

  • Open the door, take the tools and accessories that are within the sterilisation chamber, remove the wrapper and clean them.
  • Connect the power cord to a suitable power source.
  • Connect the printer (optional. It is sold separately, ref. 922-PRINTER04).
  • Switch on: The main switch is located on the right bottom area in the front panel.
  • Once activated, the LCD screen is on, where basic operation icons such as the position of the door, the water level, the sterilisation programme, date, time, etc. appear.
  • Fill tank with distilled water.
  • Remove the top lid and fill, if you hear a signal, it means that you exceeded the permitted level of water in the tank, please stop immediately and drain the amount of water necessary for the signal off.

Preparation of instruments:

  • Place instruments made of different materials in different trays, however take care to separate them before sterilisation.
  • If the instruments are not stainless steel, put some sterilisation paper between the tray and the instruments.
  • Do not allow direct contact between instruments of different materials.
  • Verify that all instruments are in correct position.
  • Place instruments such as lenses, containers, tubes, etc. inverted, so that water does not stagnate within them.
  • Do not overload the trays beyond their limit.
  • Do not overlap the trays on top of each other, or put them in direct contact with the wall of the sterilisation chamber.
  • Do not use metal clips or pins, this may impair the operation of the steriliser.
  • Wrap the instruments one by one. If you need to wrap several instruments together, make sure that they are made of the same material.
  • Seal the pouch with special adhesive tape for sterilisation or use a heat sealer.
  • Make sure that the pouch is properly positioned within the chamber on the trays (resting on the plastic part).

Choose the sterilisation programme.

Start the sterilisation cycle.

  • After selecting the sterilisation programme, insert instruments into the chamber on the trays, using the supplied plastic handle.
  • Once the instruments are placed within the chamber, close the door by turning the knob.
  • Caution: make sure to close the door, otherwise the steriliser displays an alarm and can not start or the programme stops during the cycle.

Start the sterilisation programme.

  • Press the start button, then the steriliser starts operating during approximately 30-75 minutes.

Sterilisation cycle finished.

  • After finishing the sterilisation cycle, the printer (not included*) will print the full report automatically and the data will be saved in the USB memory (.txt format).
  • After the pressure drops to zero, you can open the door and remove the instruments. The steriliser alerts by a beep once the sterilisation cycle is completed.
  • Caution: Use the supplied plastic handle for supporting trays when you take out the instruments.

IMPORTANT: Do not reuse used water.

Installation:

  • There must be at least 10 cm of free space around the steriliser, 25 cm at the top, and enough room to open the door.
  • The place where the steriliser is used must have proper ventilation.
  • The steriliser must be placed on a stable surface and at an appropriate height for handling.
  • Do not cover or block the lateral outlets or the outlet air grid of the condenser fan.
  • Do not place the steriliser near water sources.
  • Keep away from heat sources.

Example of printed report:

================================
Programme: WRAPPED

Temperature: 134C
Pressure: 206.0 kPa
Drying time: 08min
Sterilisation time: 4.0Min
--------------------------------
Time Temp. pressure
Start 12:28:17 089.0C
T1: 12:31:32 087.1C -075.0kPa
T2: 12:33:43 110.2C 052.0kPa
T3: 12:36:37 088.9C -080.0kPa
T4: 12:39:20 114.7C 053.7kPa
T5: 12:43:37 087.9C -080.0kPa
T6: 12:50:40 134.8C 206.0kPa
TS: 134.7C 209.5kPa
Max. Temperature: 135.2C
Min. Temperature: 134.3C
Max. Pressure: 214.0kPa
Min. Pressure: 204.9kPa
T7: 12:54:39 134.4C 211.4kPa
T8: 12:57:36 102.1C -060.0kPa
T9: 12:59:54 098.2C -060.0kPa
End 13:04:07 102.4C
--------------------------------
Cycle No .: 00017
Result: success
Date: 07/06/2014
SN: E54723
operator:
================================

Video:

Video ,
({{ review }})
Copyright 2004-2024 | Quirumed S.L.U. | CIF: B97267405 | Registered in the Mercantile Reg. Of Valencia. Volume 7319, Book 4620, Section 8, Folio 91, Page V-86377 | RII-AEE: 5331