Autoclave 29 litres class B extra-long chamber, printer and USB

It finishes in
day(s)
Be quick
It finishes in
day(s)
-23%
Special Price €3,421.95 Excluding VAT €2,782.07 Regular Price €4,427.99
It finishes in
day(s)
Be quick
It finishes in
day(s)
-23%
In stock
Pay securely with:
Ref: 922-STE-B23T
Steriliser with special extra long chamber for cannulas. Types of loads: solid, porous, hollow type A and B, unwrapped, with simple wrapping and double wrapping, compatible with steam sterilization. Not liquids
Description

Autoclave 29 litres class B with extra long chamber specially made for cannulas. With printer and USB port.

Programmes:

Programmes Temperature Pressure Sterilising time Overall time Type Max. load Max. load per tray
Solid 134 ºC 210 kPa 4 min 25-45 min Solid unwrapped material 5 Kg 1.5 Kg
121 ºC 110 kPa 20 min 30-60 min
Wrapped 134 ºC 210 kPa 4 min 35-60 min Solid unwrapped material 5 Kg 1.5 Kg
121 ºC 110 kPa 20 min 35-65 min Solid or hollow material with simple wrap 4 Kg 1.2 Kg
Textile 134 ºC 210 kPa 8 min 45-65 min Porous unwrapped material 1.25 Kg 0.4 Kg
Porous material simple wrapped 1.1 Kg 0.3 Kg
Porous material doble wrapped 0.75 Kg 0.25 Kg
121 ºC 110 kPa 30 min 50-75 min Hollow material simple wrapped 4 Kg 1.25 Kg
Solid or hollow material doble wrapped  2 Kg 0.6 Kg
Prion 134  ºC 210 kPa 18 min 50-75 min Porous unwrapped material 1.25 Kg 0.4 Kg
Porous material simple wrapped 1.1 Kg 0.3 Kg
Porous material doble wrapped 0.75 Kg 0.25 Kg
Hollow material simple wrapped 4 Kg 1.25 Kg
Solid or hollow material doble wrapped 2 Kg 0.6 Kg
Test B&D 134  ºC 210 kPa 3,5 min 28-35 min - - -
Test Helix 134  ºC 210 kPa 3,5 min 28-35 min - - -
Empty test - - - 20-25 min - - -
  • The minimum time required for the autoclave to be ready for use after connecting to power is 5 minutes.
  • The max. sterilisation cycle temperature of 134 ºC is 137 ºC.
  • The max. sterilisation cycle temperature of 121 ºC is 124 ºC.

Features

  • Fully automatic pre-programmed sterilisation cycles.
  • Chamber and door in stainless steel with electro-polished finish.
  • High precision control system for perfect sterilisation results.
  • User friendly interface.
  • LCD screen displays information about the process continuously.
  • Open type water tank, this feature makes it easy water filling and cleaning the tank. IMPORTANT: Do not reuse waste water.
  • Built-in printer.
  • Languages: Spanish, English, German, French, Italian, Dutch, Polish, Romanian, Czech, Latvian, Lithuanian, Hungarian and Chinese.

Safety devices

  1. Breaker
    Protects your equipment from any possibility of failure in the power supply.
    Action: Interrupts the power supply.
  2. Thermal circuit breaker.
    Protection against short circuits and possible overheating in the primary network of the transformer.
    Action: Temporary interruption (until the temperature has dropped) in the winding.
  3. Safety valve.
    Protection against a possible increase in pressure within the chamber.
    Action: Escape steam until the restoration of a normal pressure level.
  4. Micro switch to control de state of the door.
    Exercises control in adjusting the door to start a sterilisation cycle.
    Action: Transmits signal to alert the incorrect position of the door.
  5. Thermostat for heating elements in the steam generator.
    Protection againts possible overheating in the heating elements in the steam generator.
    Action: Interrupts the power supply to the heating elements in the steam generator.
  6. Thermostat for heating elements in the chamber.
    Protection against possible overheating in the heating elements in the chamber.
    Action: Interrupts the power supply to the heating elements in the chamber.
  7. Auto leveling hydraulic system.
    The hydraulic system returns to its natural if the sterilisation cycle is interrupted manually.
    Action: The internal pressure is restored automatically.
  8. Door lock.
    Effective to prevent accidental opening of the door protection.
    Action: Prevents door opening by a hydraulic locking system.

 Technical features:

  • Nominal Voltage: 220-240V; 50/60 Hz; 10A
  • Chamber dimensions: 240 x 600 mm
  • Breaker: F16A / 400V
  • Nominal power: 2200VA
  • Sterilisation temperature: 121 ºC / 134 ºC
  • Distilled water tank capacity: 2.5 L approx.
  • Operating temperature: 5 ºC / 40 ºC
  • Operating relative humidity: Max. 80%, non-condensing
  • External dimensions: 490 x 450 x 860 mm
  • Net weight: 65 Kg
  • Max. noise level: <70 dB
  • Operating atmospheric pressure: 76 / 106 kPa

Components:

  • Distilled water tank
  • LCD display
  • Printer
  • Control panel
  • Main switch
  • Key for distilled and used water drain
  • USB port
  • Safety valve
  • Ventilation grid
  • Lock system
  • Power cable
  • Label

Accessories included:

  • Steriliser
  • 3 Instrument trays
  • Base for trays
  • Tray extraction handle
  • Door adjust tool
  • 2 drain hoses
  • Door gasket
  • Instruction manual

Optional accessories and replacements:

  • Printer (Ref. 922-PRINTER04).
  • Paper roll for autoclave printer (Ref. 534-ROLLPAPER)

Autoclave - step by step:


1. Open the door, take the tools and accessories that are within the sterilization chamber, remove the wrapper and clean them.


2. Connect the power cord to a suitable power source.


3. Connect the printer.


4. Swith on: The main switch is located on the right bottom area in the front panel.

  • Once activated, the LCD screen is on, where basic operation icons such as the position of the door, the water level, the sterilisation programme, date, time, etc. appear.


5. Fill tank with distilled water.

  • Remove the top lid and fill, if you hear a signal, it means that you exceeded the permitted level of water in the tank, please stop immediately and drain the amount of water necessary for the signal off.


6. Preparation of material to be sterilised:

  • Place instruments that are of different materials in different trays, however take care to separate them before sterilisation.
  • If the instruments are not stainless steel, put some sterilisation paper between the tray and the instruments.
  • Do not allow direct contact between instruments of different materials.
  • Verify that all instruments are in correct position.
  • Place instruments such as lenses, containers, tubes, etc. inverted, so that water does not stagnate within them.
  • Do not overload the trays above their limit.
  • Do not overlap the trays on top of each other, or put them in direct contact with the wall of the sterilisation chamber.
  • Do not use metal clips or pins, this may impair the operation of the steriliser.


7. Select the sterilisation programme.


8. Start the sterilisation cycle.

  • After selecting the sterilisation programme, insert instruments into the chamber on the trays, using the supplied plastic handle.
  • Once the instruments are within the chamber, close the door.
  • Caution: Be sure to close the door, otherwise the steriliser displays an alarm and can not start or stops the programme during the cycle.


9. Start the sterilisation programme.

  • Press the start button, then the steriliser starts operating during approximately between 30-75 minutes.


10. After the sterilisation cycle.

  • After completion of the sterilisation cycle, the printer will print the full report automatically.
  • After the pressure drops to zero, you can open the door and remove the instruments. The steriliser alerts by a beep once the sterilisation cycle is completed.
  • Caution: Whenever you remove instruments, use the supplied plastic handle for supporting trays.

IMPORTANT: Do not reuse waste water.

Installation:

  • There must be at least 10 cm of free space around the steriliser, 25 cm at the top, and enough room to open the door.
  • The place where the steriliser is used must have adequate ventilation.
  • The steriliser must be placed on a stable surface and at an adequate height for handling.
  • Do not cover or block the lateral outlets or outlet grille air condenser fan.
  • Do not place the steriliser near water sources where it can be splashed.
  • Keep away from heat sources.

Example of a printed report:


================================
Programme: WRAPPED

Temperature: 134C
Pressure: 206.0 kPa
Drying time: 08min
Sterilisation time: 4.0Min
--------------------------------
Time Temp. pressure
Start 12:28:17 089.0C
T1: 12:31:32 087.1C -075.0kPa
T2: 12:33:43 110.2C 052.0kPa
T3: 12:36:37 088.9C -080.0kPa
T4: 12:39:20 114.7C 053.7kPa
T5: 12:43:37 087.9C -080.0kPa
T6: 12:50:40 134.8C 206.0kPa
TS: 134.7C 209.5kPa
Max. Temperature: 135.2C
Min. Temperature: 134.3C
Max. Pressure: 214.0kPa
Min. Pressure: 204.9kPa
T7: 12:54:39 134.4C 211.4kPa
T8: 12:57:36 102.1C -060.0kPa
T9: 12:59:54 098.2C -060.0kPa
13:04:07 End 102.4C
--------------------------------
Cycle No .: 00017
Result: success
Date: 07/06/2014
SN: E54723
operator:
================================

Regulation:

  • 93/42/EEC Directive of Health Products.
  • 97/23/EEC Pressure Equipment  Directive.
  • EN 13060 Small steam water steriliser.
  • EN 61326, EN 61000 Electromagnetic compatibility.
  • EN 61010-1, UL 61010-1 Safety requirements.
  • EN 61010-2-040, IEC 61010-2-040 Specific requirements for steam sterilisers used for treatment of medical materials.

In the UK this product needs to be inspected and certified anually. Quirumed don´t offer this service and you will need to find your own local techncian who can do this. We do however have a technical service based in Spain to cover the product during the warranty period