Autoclave 23 litres class B with USB

-13%
Special Price €2,582.99 Excluding VAT €2,099.99 Regular Price €2,975.99
-13%
Available: 08/07/2024
Pay securely with:
Ref: 922-STE-B23D
Class B autoclave with automatic operating and pre-established sterilisation programmes. Easy functioning thanks to its interface. The maximum sterilisation capacity is 23 litres. It works with distilled water.
Description

Autoclave 23 litres class B with USB and liquids programme.

 Programmes:

Programmes Temperature Pressure Sterilising Time Time total Type Max load Max Load per tray
Solid 134 ºC 210 kPa 4 min 25-45 min Solid unwrapped material 5 Kg 1.5 Kg
121 ºC 110 kPa 20 min 30-60 min
Wrapped 134 ºC 210 kPa 4 min 35-60 min Solid unwrapped material 5 Kg 1.5 Kg
121 ºC 110 kPa 20 min 35-65 min Solid or hollow material with simple wrap  4 Kg 1.2 Kg
Liquids 134ºC 210 kPa 10 min 30-55 min Liquid 1.2 Kg 0.4 Kg
121ºC 110 kPa 30 min 35-60 min
Textile 134 ºC 210 kPa 8 min 45-65 min Porous unwrapped material 1.25 Kg 0.4 Kg
Porous material simple wrapped 1.1 Kg 0.3 Kg
Porous material double wrapped 0.75 Kg 0.25 Kg
121 ºC 110 kPa 30 min 50-75 min Hollow material simple wrapped 4 Kg 1.25 Kg
Solid or hollow material double wrapped 2 Kg 0.6 Kg
Prion 134  ºC 210 kPa 18 min 50-75 min Porous unwrapped material 1.25 Kg 0.4 Kg
Porous material simple wrapped 1.1 Kg 0.3 Kg
Porous material doble wrapped 0.75 Kg 0.25 Kg
Hollow material simple wrapped 4 Kg 1.25 Kg
Solid or hollow material doble wrapped 2 Kg 0.6 Kg
Test B&D 134  ºC 210 kPa 3,5 min 28-35 min - - -
Test Helix 134  ºC 210 kPa 3,5 min 28-35 min - - -
Vacuum  Test - - - 20-25 min - - -
  • The minimum time required for the autoclave to be ready for use after connecting to power is 5 minutes.
  • The max. sterilisation cycle temperature of 134 ºC is 137 ºC
  • The max. sterilisation cycle temperature of 121 ºC is 124 ºC

Features

  • Fully automatic with preset sterilisation cycles.

  • Chamber and door in stainless steel with electro-polished finish.

  • High precision control system for perfect sterilisation results.

  • User friendly interface.

  • LCD screen displays information about the process continuously.

  • Open type water tank, this feature makes it easy water filling and cleaning the tank.

  • Languages: Spanish, English, German, French, Italian, Dutch, Polish, Romanian, Czech, Latvian, Lithuanian, Hungarian and Chinese.

Safety devices

  1. Breaker
    Protects your equipment from any possibility of failure in the power supply.
    Action: Interrupts the power supply.
  2. Thermal circuit breaker
    Protection against short circuits and possible overheating in the primary network of the transformer.
    Action: Temporary interruption (until the temperature has dropped) in the winding.
  3. Safety valve
    Protection against a possible increase in pressure within the chamber.
    Action: Escape steam until the restoration of a normal pressure level.
  4. Micro switch to control de state of the door.
    Exercises control in adjusting the door to start a sterilisation cycle.
    Action: Transmits signal to alert the incorrect position of the door.
  5. Thermostat for heating elements in the steam generator.
    Protection againts possible overheating in the heating elements in the steam generator.
    Action: Interrupts the power supply to the heating elements in the steam generator.
  6. Thermostat for heating elements in the chamber.
    Protection against possible overheating in the heating elements in the chamber.
    Action: Interrupts the power supply to the heating elements in the chamber.
  7. Auto leveling hydraulic system.
    The hydraulic system returns to its natural if the sterilisation cycle is interrupted manually.
    Action: The internal pressure is restored automatically.
  8. Door lock
    Effective to prevent accidental opening of the door protection.
    Action: Prevents door opening by a hydraulic locking system.

 Technical features:

  • Nominal Voltage: 220-240V; 50/60 Hz; 10A
  • Chamber dimensions: 247 x 450 mm
  • Breaker: F16A / 400V
  • Nominal power: 2200VA
  • Sterilisation temperature: 121 ºC / 134 ºC
  • Distilled water tank capacity: 2.5 L approx.
  • Operating temperature: 5 ºC / 40 ºC
  • Operating relative humidity: Max. 80%, non-condensing
  • External dimensions: 480 x 455 x 700 mm
  • Net weight: 51 Kg
  • Max. noise level: <70 dB
  • Operating atmospheric pressure: 76 / 106 kPa

Components:

  • Distilled water tank
  • LCD display
  • Control panel 
  • Main switch
  • Key for distilled and used water drain 
  • USB port
  • Safety valve
  • Ventilation grid
  • Lock system
  • Power cable
  • Label

Accessories included:

  • Steriliser
  • 3 Instrument trays 
  • Base for trays
  • Tray extraction handle
  • Door adjust tool
  • 2 drain hoses
  • Door gasket
  • Instruction manual

Optional accessories (not included):

  •  Ref. 922-PRINTER04: printer.

Autoclave - step by step:

1- Open the door, take the tools and accessories that are within the sterilization chamber, remove the wrapper and clean them.

2- Connect the power cord to a suitable power source.

3- Swith on: The main switch is located on the right bottom area in the front panel.
Once activated, the LCD screen is on, where basic operation icons such as the position of the door, the water level, the sterilisation programme, date, time, etc. appear.

4- Fill tank with distilled water.
Remove the top lid and fill, if you hear a signal, it means that you exceeded the permitted level of water in the tank, please stop immediately and drain the amount of water necessary for the signal off.

5- Preparation of material to be sterilised:
Place instruments that are of different materials in different trays, however take care to separate them before sterilisation.
If the instruments are not stainless steel, put some sterilisation paper between the tray and the instruments.
Do not allow direct contact between instruments of different materials.
Verify that all instruments are in correct position.
Place instruments such as lenses, containers, tubes, etc. inverted, so that water does not stagnate within them.
Do not overload the trays above their limit.
Do not overlap the trays on top of each other, or put them in direct contact with the wall of the sterilisation chamber.
Do not use metal clips or pins, this may impair the operation of the steriliser.

6- Select the sterilisation programme.

7- Start the sterilisation cycle.
After selecting the sterilisation programme, insert instruments into the chamber on the trays, using the supplied plastic handle.
Once the instruments are within the chamber, close the door.
Caution: Be sure to close the door, otherwise the steriliser displays an alarm and can not start or stops the programme during the cycle.

8. Start the sterilisation programme.
Press the start button, then the steriliser starts operating during approximately between 30-75 minutes.

9-After the sterilisation cycle.
After the pressure drops to zero, you can open the door and remove the instruments. The steriliser alerts by a beep once the sterilisation cycle is completed.