Autoclave 12 litres class B with USB and double locking system

-10%
Special Price €2,029.99 Excluding VAT €1,650.40 Regular Price €2,254.95
-10%
Available: 26/08/2024
Pay securely with:
Ref: 922-STE-B12D
Steriliser for being used in medical, dental, beauty, vet and tattoo fields. Types of loads: solid, porous, empties of A and B type, unwrapped, with simple wrapping and double wrapping, liquids and compatible with steam sterilisation.
Description

Autoclave 12 litres class B with USB  and double locking system.

Programmes:

Programmes Temperature Pressure Sterilisation time Total time Type Max. load Max. load per tray
Solid 134 ºC 210 kPa 4 min 14-30 min Solid unwrapped 4 Kg 1.2 Kg
121 ºC 110 kPa 20 min 30-45 min
Wrapped 134 ºC 210 kPa 4 min 30-45 min Solid unwrapped 3.5 Kg 1.1 Kg
121 ºC 110 kPa 20 min 35-55 min Solid or hollow simple wrapped 3.5 Kg 1.1 Kg
Liquids 134 ºC 210 kPa 10 min 25-50 min Liquid 0,60 Kg 0,20 Kg
121 ºC 110 kPa 30 min 30-55 min
Textile 134 ºC 210 kPa 8 min

 

30-50 min

Porous unwrapped 1 Kg 0.3 Kg
Porous simple wrapped 0.75 Kg 0.20 Kg
Porous doble wrapped 0.50 Kg 0.15 Kg
121 ºC 110 kPa 30 min 40-60 min Hollow simple wrapped 3.5 Kg 1 Kg
Solid or hollow doble wrapped 1.5 Kg 0.5 Kg
Prion 134  ºC 210 kPa 18 min 35-55 min Porous unwrapped 1 Kg 0.3 Kg
Porous simple wrapped 0.75 Kg 0.20 Kg
Porous doble wrapped 0.50 Kg 0.15 Kg
Hollow simple wrapped 3.5 Kg 1 Kg
Solid or hollow doble wrapped 1.5 Kg 0.5 Kg
B&D test 134  ºC 210 kPa 3.5 min 22-35 min - - -
Helix test 134  ºC 210 kPa 3.5 min 22-35 min - - -
Vacuum test - - - 18-20 min - - -
  • The minimum time required for the autoclave to be ready for use after switching on is 5 minutes.
  • The maximum temperature for the 134 ºC sterilisation cycle is 137 ºC.
  • The maximum temperature for the 121 ºC sterilisation cycle is 124 ºC.

Features

  • Fully automatic with pre-programmed sterilisation cycles.
  • Chamber and door in stainless steel with electro-polished finish.
  • High precision control system for perfect sterilisation results.
  • User friendly interface.
  • LCD screen displays continuously information about the process.
  • Open type water tank, this feature makes water filling and cleaning the tank easy. IMPORTANT: Do not reuse dirty water.
  • Languages: Spanish, English, German, French, Italian, Dutch, Polish, Romanian, Czech, Latvian, Lithuanian, Hungarian and Chinese.

Safety devices

Breaker.
Protect your computer from any possibility of failure in the power supply.
Action: Interrupt the power supply.
Thermal circuit breaker.
Protection against short circuits and possible overheating in the transformer primary network.
Action: Temporary interruption (until the temperature has dropped) in the winding.
Safety valve.
Protection against a possible increase in pressure within the chamber.
Action: Escape steam until the restoration of a normal pressure level.
Micro switch to control the state of the door.
Exercises control in adjusting the door to start a sterilization cycle.
Action: Transmits signal to alert the incorrect position of the door.
Thermostat for heating elements in the steam generator.
Protection against possible overheating in the heating elements in the steam generator.
Action: interrupts the power supply to the heating elements in the steam generator.
Thermostat for heating elements in the chamber.
Protection against possible overheating in the heating elements in the chamber.
Action: interrupts the power supply to the heating elements in the chamber.
Auto leveling hydraulic system.
The hydraulic system pressure returns to its natural if the sterilization cycle is interrupted manually.
Action: the internal pressure is restored automatically.
Door Lock
Effective to prevent accidental opening of the door protection.
Action: Prevents door opening by a hydraulic locking system.

 Technical features:

  • Power supply: 220-240V; 50/60 Hz; 10A
  • Chamber: 200 x 360 mm
  • Breaker: F16A / 400V
  • Nominal power: 2200VA
  • Sterilisation temperature: 121 ºC / 134 ºC
  • Capacity of the distilled water tank: 2.5 L approx.
  • Working temperature: 5 ºC / 40 ºC
  • Working relative humidity: Max. 80%, non condensing
  • Overall dimensions: 414 x 365 x 570 mm
  • Net weight: 51 Kg
  • Max. noise level: <70 dB
  • Atmospheric pressure: 76 / 106 kPa

Components:

  • Distilled water tank
  • LCD display
  • Control panel
  • Main power switch
  • Drain conector (distilled and used water tank)
  • USB port
  • Safety valve
  • Ventilation grid
  • Circuit breaker
  • Power cable
  • Rating plate

Accessories included:

  • Steriliser
  • 3 trays for instruments
  • Tray rack
  • Tray holder
  • Door adjustment tool
  • 2 draining hoses
  • Door gasket
  • User manual

Printer not included (ref. 922-PRINTER04).

AUTOCLAVE - step by step:

1- Open the door, take the tools and accessories that are within the sterilisation chamber, remove the wrapper and clean them.

2- Connect the power cord to a suitable power source.

3- Swith on: The main switch is located on the right bottom area in the front panel.

  • Once activated, the LCD screen is on, where basic operation icons such as the position of the door, the water level, the sterilisation programme, date, time, etc. appear.

4- Fill tank with distilled water.

  • Remove the top lid and fill, if you hear a signal, it means that you exceeded the permitted level of water in the tank, please stop immediately and drain the amount of water necessary for the signal off.

5- Preparation of material to be sterilised:

  • Place instruments that are of different materials in different trays, however take care to separate them before sterilisation.
  • If the instruments are not stainless steel, put some sterilisation paper between the tray and the instruments.
  • Do not allow direct contact between instruments of different materials.
  • Verify that all instruments are in correct position.
  • Place instruments such as lenses, containers, tubes, etc. inverted, so that water does not stagnate within them.
  • Do not overload the trays above their limit.
  • Do not overlap the trays on top of each other, or put them in direct contact with the wall of the sterilisation chamber.
  • Do not use metal clips or pins, this may impair the operation of the steriliser.

6- Choose the sterilisation programme.

7- Start the sterilisation cycle.

  • After selecting the sterilisation programme, insert instruments into the chamber on the trays, using the supplied plastic handle.
  • Once the tools are placed within the chamber, proceed to close the door by turning the knob.
  • Caution: Be sure to close the door, otherwise the steriliser displays an alarm and can not start or stops the programme during the cycle.

8- Start the sterilisation programme.

  • Press the start button, then the steriliser starts operating during approximately between 30-75 minutes.

9- Sterilisation cycle finished.

  • After finishing the sterilisation cycle, the printer (not included*) will print the full report automatically.
  • After the pressure drops to zero, you can open the door and remove the instruments. The steriliser alerts by a beep once the sterilisation cycle is completed.
  • Caution: Whenever you remove instruments, use the supplied plastic handle for supporting trays.

* The printer is purchased separately. Reference: 922-PRINTER04.

IMPORTANT: Do not reuse used water.

Installation:

  • There must be at least 10 cm of free space around the steriliser, 25 cm at the top, and enough room to open the door.
  • The place where the steriliser is used must have appropriate ventilation.
  • The steriliser must be placed on a stable surface and at an appropriate height for handling.
  • Do not cover or block the lateral outlets or the outlet air grid of the condenser ventilator.
  • Do not place the steriliser near water sources where it can be splashed.
  • Keep away from heat sources.

Example of printed report:

================================
Programme: WRAPPED

Temperature: 134C
Pressure: 206.0 kPa
Drying time: 08min
Sterilisation time: 4.0Min
--------------------------------
Time Temp. pressure
Start 12:28:17 089.0C
T1: 12:31:32 087.1C -075.0kPa
T2: 12:33:43 110.2C 052.0kPa
T3: 12:36:37 088.9C -080.0kPa
T4: 12:39:20 114.7C 053.7kPa
T5: 12:43:37 087.9C -080.0kPa
T6: 12:50:40 134.8C 206.0kPa
TS: 134.7C 209.5kPa
Max. Temperature: 135.2C
Min. Temperature: 134.3C
Max. Pressure: 214.0kPa
Min. Pressure: 204.9kPa
T7: 12:54:39 134.4C 211.4kPa
T8: 12:57:36 102.1C -060.0kPa
T9: 12:59:54 098.2C -060.0kPa
13:04:07 End 102.4C
--------------------------------
Cycle No .: 00017
Result: success
Date: 07/06/2014
SN: E54723
operator:
================================

Standards:

  • 93/42/EEC Directive on Medical Devices.
  • 97/23/EEC Directive on Pressure Equipment.
  • EN 13060 Small Steam Sterilisers.
  • EN 61326, EN 61000 Electromagnetic Compatibility.
  • EN 61010-1, UL 61010-1 Safety requirements.
  • EN 61010-2-040, IEC 61010-2-040 Specific requirements for steam sterilisers used for treatment of medical materials.

In the UK this product needs to be inspected and certified anually. Quirumed don´t offer this service and you will need to find your own local techncian who can do this. We do however have a technical service based in Spain to cover the product during the warranty period